The RadPRO Mobile 40kW Flex Digital X-ray System, is a portable x-ray system that incorporates a new telescopic tube column helping radiographic technologists to maximize their lines of vision for safe transport when moving around a healthcare facility.  The new functionality builds on the ease of maneuvering and positioning that is a hallmark of the current RadPRO Mobile 40kW System, while maintaining the ability to capture high-quality diagnostic images for routine diagnosis or challenging trauma directly from a patients’ bed.

Request Quote

Product Features

  • Telescopic tube column maximizes lines of vision for safe transport
  • New lead crystal batteries retain power longer, eliminating the need to recharge more frequently
  • Dual battery configuration allows for distributed power to the drive motors, as well as the generator
  • Secondary drive controls on the collimator handles allow the system to be positioned without the need to return to the main console
  • A patent-pending wireless distributed antennae system that can increase wireless range 40% over single access point systems
  • Integrates with choice of Canon CXDI 401C/701C/801C wireless flat panel detectors 
  • 40 kW x-ray generator (40-150 kVp) 
  • 300 khu x-ray tube 
  •  0.7,1.3mm focal spots
  • 16 degree target angle (important for being able to take images at shorter SID without adverse heel-effect)  
  • Faster Battery charge time (11% minimum)
  • Additional spectral filtration in collimator
  • Laser light-field indicator 

Specifications

COUNTERBALANCED TUBE ARM

Tube arm reach 49.2 inch (1,250 mm) Column rotation: ± 315°
Maximal SID to floor 80.7 inch (2,050 mm)
Minimal SID to floor 21.6 inch (550 mm)

Mobile Unit

Weight 1,268 lbs (575 kg) standard unit 1,312 lbs (595 kg) unit with telescopic column
Size (L x W x H) 53.54 x 26.4 x 77.9 inch (1,360 x 670 x 1,980 mm)
Touch screen console 17 inch (430 mm) diagonal
Anti-collision system Frontal
Motorized unit Up to 4 km/h
Motor Drive (Standard)  Two (2) independent drive motors, one for each wheel (forward and reverse)

GENERATOR SPECS

kW Rating 40 kW
kVp Range 40 to 150 kVp
mA Range 10 – 500 mA Selectable
Number of Stations 18
Exposure Time Range 0.001 – 10 sec.
mAs Range 0.1 – 500 mAs
Generator Integration Yes, 3 PT technique
Battery Capacitor Battery / Capacitor
Anatomical Programs 500+ Anatomical settings
Line Requirements  Single Phase Line Regulation from 100 – 240 Vac (+/-10%)

Resources

  • Telescopic tube column maximizes lines of vision for safe transport
  • New lead crystal batteries retain power longer, eliminating the need to recharge more frequently
  • Dual battery configuration allows for distributed power to the drive motors, as well as the generator
  • Secondary drive controls on the collimator handles allow the system to be positioned without the need to return to the main console
  • A patent-pending wireless distributed antennae system that can increase wireless range 40% over single access point systems
  • Integrates with choice of Canon CXDI 401C/701C/801C wireless flat panel detectors 
  • 40 kW x-ray generator (40-150 kVp) 
  • 300 khu x-ray tube 
  •  0.7,1.3mm focal spots
  • 16 degree target angle (important for being able to take images at shorter SID without adverse heel-effect)  
  • Faster Battery charge time (11% minimum)
  • Additional spectral filtration in collimator
  • Laser light-field indicator 

COUNTERBALANCED TUBE ARM

Tube arm reach 49.2 inch (1,250 mm) Column rotation: ± 315°
Maximal SID to floor 80.7 inch (2,050 mm)
Minimal SID to floor 21.6 inch (550 mm)

Mobile Unit

Weight 1,268 lbs (575 kg) standard unit 1,312 lbs (595 kg) unit with telescopic column
Size (L x W x H) 53.54 x 26.4 x 77.9 inch (1,360 x 670 x 1,980 mm)
Touch screen console 17 inch (430 mm) diagonal
Anti-collision system Frontal
Motorized unit Up to 4 km/h
Motor Drive (Standard)  Two (2) independent drive motors, one for each wheel (forward and reverse)

GENERATOR SPECS

kW Rating 40 kW
kVp Range 40 to 150 kVp
mA Range 10 – 500 mA Selectable
Number of Stations 18
Exposure Time Range 0.001 – 10 sec.
mAs Range 0.1 – 500 mAs
Generator Integration Yes, 3 PT technique
Battery Capacitor Battery / Capacitor
Anatomical Programs 500+ Anatomical settings