Konica Automated OTC

Taking digital radiography to the next level.
Radiographic Ceiling Suspension Tube Stand • Auto-Position Elevating Table
The Automated OTC is an integrated system for all conventional radiographic applications in combination with a high-frequency generator, radiographic table, and wall bucky. The system has been designed focusing on flexibility and friendly use. It can also be configured depending on your exact clinical requirements.

Ceiling Suspension Tube Stand Fully Automatic The heavy-duty X-ray tube overhead support system is characterized by its simple and functional design. With its new light weight design, it guarantees highly precise positioning for an optimal radiographic result.

Thanks to its vertical and horizontal displacements, the overhead tube crane (OTC) can cover almost all the volume of the room in which it is installed. The new OTC support system can operate on a horizontal or vertical bucky, or be installed with an elevating table.

  • Positioning precision and speed
  • Fully electronic self positioning
  • Plug in and modular electrical assemblies to facilitate the installation, calibration and maintenance
  • X-Ray support with 360º vertical and horizontal rotationFor the fully automatic ceiling suspension version there are two different motorized automatic movement’s, auto-positioning and auto-tracking.

Auto-Positioning
Pre-configured positioning can be selected from the control station with two options:

  • Auto-Positioning with the Radiographic table: The suspension automatically positions itself above the table according to the SID specified during the configuration
  • Auto-Positioning with the Wall-Stand: The suspension automatically positions itself in front of the vertical bucky or receptor according to the SID specified during configuration

Auto-Tracking
There are two tracking movements of the tube with respect to the receptor and bucky.

  • Fully Automated Tracking: Starting from a standard position, auto-tracking is carried out according to the position of the receptor throughout all of its axes, maintaining the relative initial geometry (spatial orientation).
  • Tracker: From any position in which the primary beam of the X-rays cuts the detector, the auto-tracking will be limited, without angulations when the selected workstation button is pressed. There are two possible combinations.Suspension Overhead Tube Crane (OTC) with Wall Stand When manually moving the receptor, the suspension will move to the requested SID in parallel until it is centered with the bucky. If this is done while in tilting, the OTC will maintain the vertical and perpendicular SID constant by rotating around the receptor. Suspension OTC with Table Both receptor and suspension operate by motorized movement followed by auto-centering. Tilting Wall Stand Vertical Motorization Auto-Position System possibility of auto-tracking and auto-positioning with the ceiling suspension

Suspension Overhead Tube Crane (OTC) with Wall Stand When manually moving the receptor, the suspension will move to the requested SID in parallel until it is centered with the bucky. If this is done while in tilting, the OTC will maintain the vertical and perpendicular SID constant by rotating around the receptor.

Suspension OTC with Table Both receptor and suspension operate by motorized movement followed by auto-centering.

Tilting Wall Stand Vertical Motorization Auto-Position System possibility of auto-tracking and auto-positioning with the ceiling suspension