Our Products

Canon DR Tablet Soulution

Easily make the move to digital radiography. The Solution consists of a tablet* and choice of a wireless CXDI Digital Radiography (DR) System, which includes CXDI Control Software NE. The CXDI Control Software NE’s auto-detection mode allows the CXDI detector to automatically detect X-rays at exposure without the use of a typical X-ray generator interface. The tablet’s unique Wi-Fi®capability allows end-users to communicate wirelessly with both the CXDI detector and the DICOM® network. Images can be acquired from the CXDI detector while previous images are simultaneously sent to PACS.

Request Quote

Product Features

  • Solution comprised of the tablet, CXDI Wireless DR System, and CXDI Control Software NE
  • Tablet has rugged construction and is drop and scratch-resistant
  • Built-in disaster recovery capability in the tablet allows you to backup and restore onsite within minutes
  • The CXDI DR Systems incorporate the Canon LANMIT® (Large Area New Metal-lnsulator Semiconductor) technology and a proprietary glass substrate for high-resolution, high-contrast images.
  • The CXDI Wireless DR Systems have a Csl scintillator that optimizes light channeling and produces high-quality images at a low X-ray exposure to the patient.
  • CXDI Control Software NE provides quick image confirmation and timely network distribution, supports multiple study acquisition, can be easily tailored to individual clinical preferences, and helps provide the delivery of consistent, high-resolution image with the Canon CXDI Digital Radiography Systems.
  • CXDI Control Software NE includes streamlined workflow, stitching, and enhanced visualization protocol (EVP)

Specifications

Tablet Specifications

Operating System Windows® 7 Professional 64-bit
CPU Intel® CoreTM i5-5350U vProTM 1.8GHz processor (Broadwell 5th generation)
Memory 8GB DDR3L
Storage 256GB mSATA SSD
Display

10.1 in WUXGA (1920 x 1200), 1000 nits sunlight readable

10-point capacitive touch supports glove touch, water rejection, palm rejection, 2mm hard tip stylus

Gorilla Glass3 Digitizer (option)

Graphic  Intel i5-5350U: Intel HD Graphics 6000
RF Wi-Fi 802.11 a/b/g/n/ac Bluetooth V4.0
Data Collection  2D barcode reader
Control Button  Barcode trigger x 1 Power, volume
Sensor Gyroscope, G-sensor, E-compass, light sensor
Power Adapter  AC 100V~240V, 50~60Hz Input; [email protected], 65W
Battery Life Cycle  Standard : 4500mAh, 10.8V, hot swappable battery
Dimensions and Weight  11 in x 7.7 in x 0.9 in (28 cm x 19.5 cm x 2.3 cm) 3.0 lbs (1. 36 kg)
LED Indicator

 Power on/off

Wi-Fi on/off

Fn on/off

Battery full /charging/low

Rugged Features  IP65, MIL-S TD-810G, shock & vibration, 5 feet drop
Environment

Operating temperature -4° F to 140° F (-20° C to 60°C) 

Storage temperature -22° F to 158° F (-30° C to 70°C)

Humidity 5%~95%

Security TPM 1.2
CXDI-401C WIRELESS DIGITAL RADIOGRAPHY SYSTEM
Image Area 17 in x 16 in
Weight 8.4 lbs w/ battery
Pixels 3,408 x 3,320
Pixel Pitch 125 microns
A/D 16-bit
Grayscale Output  12-bit or 16-bit
CXDI-701C WIRELESS DIGITAL RADIOGRAPHY SYSTEM
Image Area 14 in x 17 in
Weight 7.3 lbs w/ battery
Pixels 2,800 x 3,408
Pixel Pitch 125 microns
A/D 16-bit
Grayscale Output  12-bit or 16-bit
CXDI-801C WIRELESS DIGITAL RADIOGRAPHY SYSTEM
Image Area 11 in x 14 in
Weight 5.1 lbs w/ battery
Pixels 2,192 x 2,800
Pixel Pitch 125 microns
A/D 16-bit
Grayscale Output  12-bit or 16-bit

Resources

  • Solution comprised of the tablet, CXDI Wireless DR System, and CXDI Control Software NE
  • Tablet has rugged construction and is drop and scratch-resistant
  • Built-in disaster recovery capability in the tablet allows you to backup and restore onsite within minutes
  • The CXDI DR Systems incorporate the Canon LANMIT® (Large Area New Metal-lnsulator Semiconductor) technology and a proprietary glass substrate for high-resolution, high-contrast images.
  • The CXDI Wireless DR Systems have a Csl scintillator that optimizes light channeling and produces high-quality images at a low X-ray exposure to the patient.
  • CXDI Control Software NE provides quick image confirmation and timely network distribution, supports multiple study acquisition, can be easily tailored to individual clinical preferences, and helps provide the delivery of consistent, high-resolution image with the Canon CXDI Digital Radiography Systems.
  • CXDI Control Software NE includes streamlined workflow, stitching, and enhanced visualization protocol (EVP)

Tablet Specifications

Operating System Windows® 7 Professional 64-bit
CPU Intel® CoreTM i5-5350U vProTM 1.8GHz processor (Broadwell 5th generation)
Memory 8GB DDR3L
Storage 256GB mSATA SSD
Display

10.1 in WUXGA (1920 x 1200), 1000 nits sunlight readable

10-point capacitive touch supports glove touch, water rejection, palm rejection, 2mm hard tip stylus

Gorilla Glass3 Digitizer (option)

Graphic  Intel i5-5350U: Intel HD Graphics 6000
RF Wi-Fi 802.11 a/b/g/n/ac Bluetooth V4.0
Data Collection  2D barcode reader
Control Button  Barcode trigger x 1 Power, volume
Sensor Gyroscope, G-sensor, E-compass, light sensor
Power Adapter  AC 100V~240V, 50~60Hz Input; [email protected], 65W
Battery Life Cycle  Standard : 4500mAh, 10.8V, hot swappable battery
Dimensions and Weight  11 in x 7.7 in x 0.9 in (28 cm x 19.5 cm x 2.3 cm) 3.0 lbs (1. 36 kg)
LED Indicator

 Power on/off

Wi-Fi on/off

Fn on/off

Battery full /charging/low

Rugged Features  IP65, MIL-S TD-810G, shock & vibration, 5 feet drop
Environment

Operating temperature -4° F to 140° F (-20° C to 60°C) 

Storage temperature -22° F to 158° F (-30° C to 70°C)

Humidity 5%~95%

Security TPM 1.2
CXDI-401C WIRELESS DIGITAL RADIOGRAPHY SYSTEM
Image Area 17 in x 16 in
Weight 8.4 lbs w/ battery
Pixels 3,408 x 3,320
Pixel Pitch 125 microns
A/D 16-bit
Grayscale Output  12-bit or 16-bit
CXDI-701C WIRELESS DIGITAL RADIOGRAPHY SYSTEM
Image Area 14 in x 17 in
Weight 7.3 lbs w/ battery
Pixels 2,800 x 3,408
Pixel Pitch 125 microns
A/D 16-bit
Grayscale Output  12-bit or 16-bit
CXDI-801C WIRELESS DIGITAL RADIOGRAPHY SYSTEM
Image Area 11 in x 14 in
Weight 5.1 lbs w/ battery
Pixels 2,192 x 2,800
Pixel Pitch 125 microns
A/D 16-bit
Grayscale Output  12-bit or 16-bit