Our Products

Canon CXDI-501C Digital Radiography System

The CXDI-501C Digital Radiography (DR) System has improved diagnostic quality with 125 micron pixel pitch resulting in high resolution. The Digital Radiography scope expands with high resolution quality, high sensitivity and high signal to noise performance. By eliminating cassette handling and providing image preview 3 seconds after exposure, more time can be available to concentrate on critical tasks. Configurations are available for upright stands, U-arm stands, Bucky tables or retrofit solutions.

Request Quote

Product Features

  • High Resolution and High Sensitivity 
    With a 125 micron pixel pitch, the CXDI-501C Digital Radiography (DR) System delivers exceptional spatial resolution. The high sensitivity of the Cesium Iodide (CsI) scintillator helps reduce the X-ray exposure to the patient. The maximum 3 second exposure time allows this digital detector to be used with tomography equipment and for other exams that may require an exposure time of up to 3 seconds.
  • True Portability with Detachable Cable 
    Weighing less than 7 pounds, either the patient or the x-ray technician may comfortably hold the CXDI-501C DR System in place during image capture. The built-in groove in the detector also helps maneuver the detachable cable easily.
  • CXDI Control Software NE 
    The CXDI-501C Digital Radiography System uses the Canon CXDI Control Software NE. The software gives a wide range of selections and images can be taken within three touches. An on-screen preview image is available 3 seconds after exposure. The image processing shows subtle details of trabecular bone structure and soft tissue in the same image. For more information, visit our CXDI Control Software NE webpage.
  • Printers and Projectors 
    If your imaging requirements include color or black-and-white prints in a variety of sizes, Canon printers offer a terrific blend of print quality, ease-of-use, speed, and cost-effective operation. For teaching facilities and conference rooms, Canon’s high quality projectors provide LCOS (liquid crystal on silicon) technology, which is engineered to provide exceptional color, intricate details, and easy-to-read type.

Specifications

Detector:

Method Flat Panel Detector, Scintillator & Amorphous Silicon (a-Si)
Scintillator Csl (Csl: TI)
Sensor LANMIT (Large Area New-MIS sensor and TFT)
Pixel Pitch 125 Microns
Pixels 2,800 x 3,408 Pixels (9.5 Megapixels)
Imaging Area Approximately 14 x 17 in (35 x 42.6 cm)
Standard Components  Sensor Unit, Power Box, Remote Switch, X-ray Interface Cable

Image Acquisition and Processing

Image Processing Standard Advanced Multi-Frequency Processing
A/D 14-bit
Grayscale 4,096 Grayscale (12-bit)
Preview Image Approximately 3 Seconds After X-ray Exposure
Full Image Display Approximately 5 Seconds After X-ray Exposure

Data output and network connection

Network Ethernet 10/100/1000 Base T, RJ45 Standard, Wireless Optional
DICOM  DICOM 3.0 Compatible, Print Management Service Class (SCU), Storage Service Class (SCU), and Others

Electrical and Environmental

Voltage AC 100-240V 50/60Hz
Operating Environment Sensor unit: 41-95°F (5-35°C), Humidity 30-80% RH (non-condensing)

Physical Characteristics

Dimensions (WxLxH) 18.1 x 16.7 x 0.6 in (460 x 424 x 15 mm)
Weight  6.8 lbs (3 kg)

Resources

  • High Resolution and High Sensitivity 
    With a 125 micron pixel pitch, the CXDI-501C Digital Radiography (DR) System delivers exceptional spatial resolution. The high sensitivity of the Cesium Iodide (CsI) scintillator helps reduce the X-ray exposure to the patient. The maximum 3 second exposure time allows this digital detector to be used with tomography equipment and for other exams that may require an exposure time of up to 3 seconds.
  • True Portability with Detachable Cable 
    Weighing less than 7 pounds, either the patient or the x-ray technician may comfortably hold the CXDI-501C DR System in place during image capture. The built-in groove in the detector also helps maneuver the detachable cable easily.
  • CXDI Control Software NE 
    The CXDI-501C Digital Radiography System uses the Canon CXDI Control Software NE. The software gives a wide range of selections and images can be taken within three touches. An on-screen preview image is available 3 seconds after exposure. The image processing shows subtle details of trabecular bone structure and soft tissue in the same image. For more information, visit our CXDI Control Software NE webpage.
  • Printers and Projectors 
    If your imaging requirements include color or black-and-white prints in a variety of sizes, Canon printers offer a terrific blend of print quality, ease-of-use, speed, and cost-effective operation. For teaching facilities and conference rooms, Canon’s high quality projectors provide LCOS (liquid crystal on silicon) technology, which is engineered to provide exceptional color, intricate details, and easy-to-read type.

Detector:

Method Flat Panel Detector, Scintillator & Amorphous Silicon (a-Si)
Scintillator Csl (Csl: TI)
Sensor LANMIT (Large Area New-MIS sensor and TFT)
Pixel Pitch 125 Microns
Pixels 2,800 x 3,408 Pixels (9.5 Megapixels)
Imaging Area Approximately 14 x 17 in (35 x 42.6 cm)
Standard Components  Sensor Unit, Power Box, Remote Switch, X-ray Interface Cable

Image Acquisition and Processing

Image Processing Standard Advanced Multi-Frequency Processing
A/D 14-bit
Grayscale 4,096 Grayscale (12-bit)
Preview Image Approximately 3 Seconds After X-ray Exposure
Full Image Display Approximately 5 Seconds After X-ray Exposure

Data output and network connection

Network Ethernet 10/100/1000 Base T, RJ45 Standard, Wireless Optional
DICOM  DICOM 3.0 Compatible, Print Management Service Class (SCU), Storage Service Class (SCU), and Others

Electrical and Environmental

Voltage AC 100-240V 50/60Hz
Operating Environment Sensor unit: 41-95°F (5-35°C), Humidity 30-80% RH (non-condensing)

Physical Characteristics

Dimensions (WxLxH) 18.1 x 16.7 x 0.6 in (460 x 424 x 15 mm)
Weight  6.8 lbs (3 kg)